产品名称Thermoset GF-1400

所属分类灌封材料
概要信息
描述LORD ThermosetTM GF-1400导热硅隙填料是一种双组分系统,用于为电子应用提供良好的导热性。
产品描述

描述LORD ThermosetTM GF-1400导热硅隙填料是一种双组分系统,用于为电子应用提供良好的导热性。

LORD ThermosetTM GF-1400 thermally conductive silicone gap filler is a two-component system designed to provide excellent thermal conductivity for electronic applications, while retaining desirable properties associated with silicones.

 

Features and Benefits

Low Stress – exhibits low shrinkage and stress on components as it cures.

Durable – composed of an addition-curing polydimethyl siloxane polymer that will not depolymerize when heated in confined spaces.

Environmentally Resistant – provides excellent thermal shock resistance.

 

Application

Mixing – Mix Thermoset GF-1400 resin with Thermoset GF-1400 hardener at a 1:1 ratio, by weight or volume. Handheld cartridges or automatic meter/mix/dispense equipment should be used to avoid any air entrapment in the material. Manual mixing is not recommended.

Applying – Apply material using handheld cartridges or automatic meter/mix/dispense equipment.

· Handheld Cartridges

1. Load the cartridge into the applicator gun and remove the end caps.

2. Level the plungers by expelling a small amount of material to ensure both sides are level.

3. Attach mixing tip and expel a mixer’s length of material.

4. Apply material to substrate and mate the parts within the working time of the gap filler. Clamp in position until material reaches handling strength.

· Meter/Mix/Dispense Equipment

Contact your LORD representative if assistance is needed using this equipment.

Avoid applying Thermoset GF-1400 gap filler to surfaces that contain cure inhibiting ingredients, such as amines, sulfur or tin salts. If bonding surface is in question, apply a test patch of Thermoset GF-1400 gap filler to the surface and allow it to set for the normal cure time. A liquid layer of silicone will remain on the surface if an inhibitor is present.

Typical Properties*

Typical Cured Properties**

Curing – Allow material to cure for 24 hours at room temperature (25°C) or for 60 minutes at 100°C. This time-at-temperature profile refers to the time the material should be allowed to cure once it reaches the target temperature. Allowance should be made for oven ramp rates, parts with large thermal mass and other circumstances that may delay material reaching the target temperature.

Shelf Life/Storage

Shelf life of each component is three months from date of manufacture when stored at 25°C in original, unopened container.

Thermoset GF-1400 gap filler evolves minute quantities of hydrogen gas. Do not repackage or store material in unvented containers. Adequately ventilate work area to prevent the accumulation of gas.

Cautionary Information

Before using this or any LORD product, refer to the Safety Data Sheet (SDS) and label for safe use and handling instructions.

For industrial/commercial use only. Must be applied by trained personnel only. Not to be used in household applications. Not for consumer use.